Railings, Window Screens and Window Guards in Toronto Rentals: What Chapter 629 Requires
A part-by-part walk around a rental property, from the backyard deck to the apartment window, reading what Toronto’s property standards by-law actually says.
What does Toronto’s property standards by-law require for railings and windows in a rental home?
Under §629-19C of Toronto Municipal Code Chapter 629, a required guard is generally at least 1,070 mm high; guards inside a dwelling unit, and exterior guards serving one unit where the walking surface is no more than 1,800 mm above finished ground, can be 900 mm; and openings in a required guard must stop a 100 mm sphere. Separately, every window in a dwelling unit that can be opened must have a screen kept in good repair (§629-21B), and in apartment buildings, a window more than 2,000 mm above grade that opens within 1,500 mm of the floor needs fall protection under §629-19D(4).
Source: City of Toronto Municipal Code, Chapter 629, Property Standards, §§629-19 and 629-21 (consolidation current to April 30, 2025)
I’m Arthur Zhao with AZ Real Estate Partners. Picture a landlord who rents out a semi-detached house. The tenants move out at the end of the month, the new ones arrive two weeks later, and the old wooden deck out back has a railing that wobbles when you lean on it. The plan is to tear it off and build a new one in that gap. Before buying lumber, the landlord wants two numbers: how tall the new railing has to be, and how far apart the balusters can sit without falling short of the city’s rules.
Those numbers are in Chapter 629 of the Toronto Municipal Code, the property standards by-law. Section 629-2 says the chapter “applies to all property in the City of Toronto,” so it is not a rental-only rulebook; it is the baseline for every house, and a landlord meets it twice, once as a property owner and again through the Residential Tenancies Act. The deck is a good place to start reading it, because once you know how the by-law treats a railing out back, the rest of the property follows the same logic.
→
→
→
→
→
Outdoor decks, porches and balconies
Start with which part of §629-19 applies. Subsection C covers buildings of three or fewer storeys with a building area not exceeding 600 square metres, used for residential and certain other occupancies. That captures the detached house, the semi and the small converted house. Anything larger, more than three storeys or more than 600 m², or used for occupancies outside C, falls under Subsection D. The deck in our example sits behind a semi of three storeys or fewer and under 600 m², so it is a Subsection C question.
Does the deck need a guard at all? Under §629-19C(1)(a), a porch, deck, balcony, landing or other surface people use (other than for maintenance) must have a guard on each side not protected by a wall where either:
- the walking surface is more than 600 mm above the adjacent surface, or
- the adjacent surface within 1.2 metres of the walking surface slopes more than one vertical to two horizontal.
How tall? §629-19C(2) sets the heights:
- the general rule is not less than 1,070 mm (C(2)(a));
- guards within dwelling units: not less than 900 mm (C(2)(b));
- exterior guards serving not more than one dwelling unit: not less than 900 mm, where the walking surface is not more than 1,800 mm above finished ground (C(2)(c));
- guards for flights of steps, except required exit stairs: not less than 900 mm (C(2)(d)).
One detail for a house with more than one unit: the 900 mm exterior figure in C(2)(c) is written for a guard serving “not more than one dwelling unit.” A deck shared by a main-floor unit and a basement unit is not described by that wording, so reading the text, it falls back to the general 1,070 mm. Whatever the height, §629-19A requires decks, porches, balconies and the guards and supports attached to them to be free from defects and hazards, able to carry their loads, and in good repair.
For the larger buildings under Subsection D, §629-19D(1)(a) requires a guard of not less than 1,070 mm at balconies and other locations where the difference in level is more than 600 mm, and §629-19D(3)(d) raises guards on exterior stairs and landings more than 10 metres above adjacent ground to not less than 1,500 mm.
Baluster spacing depends on whether the guard was required in the first place
💡 My reading of §629-19C(4)(a): the 100 mm sphere is the default, not an absolute. The clause adds “unless it can be shown that the location and size of openings that exceed this limit do not represent a hazard.” The sentence is built so that the 100 mm limit governs unless someone makes that showing, which means the burden sits with whoever wants the larger opening to stand. The by-law text does not say what evidence is enough or who decides it; if a specific railing depends on that clause, the building’s owner should get advice from a qualified designer or a lawyer rather than assume it applies.
Choosing the new railing design: climbing and glass
Height and spacing are not the whole rule for a required guard. §629-19C(5)(a) says guards required by C(1), except in industrial occupancies and where it can be shown the openings do not represent a hazard, must be designed so that no member, attachment or opening will facilitate climbing. §629-19C(5)(b) then lists when a guard is deemed to comply. It looks at elements protruding from the vertical in the zone between 140 mm and 900 mm above the walking surface, and the guard is deemed to comply where those elements:
- are located more than 450 mm horizontally and vertically from each other;
- provide not more than 15 mm horizontal offset;
- do not provide a toe-space more than 45 mm horizontally and 20 mm vertically; or
- present more than a slope of one vertical to two horizontal on the offset.
On my reading, a horizontal rail fixed low across the balusters is the kind of element that zone describes. If the new railing uses glass panels, §629-19C(6) requires safety glass of the laminated or tempered type conforming to CAN/CGSB-12.1-M, or wired glass conforming to CAN/CGSB-12.11-M.
Chapter 629 is a maintenance and occupancy standard. Whether rebuilding a deck also needs a building permit, or must meet further Building Code requirements, is a separate question for the City’s building division or the person designing the work.
Stairs, inside and out
From the deck, follow the steps down to the yard and then walk through the house. Two rules carry over:
- Exterior steps: guards for flights of steps, except in required exit stairs, must be not less than 900 mm high (§629-19C(2)(d)), measured vertically from a line drawn through the leading edge of the treads (§629-19C(2)(e)). Whether the steps need a guard at all goes back to the C(1)(a) test: more than 600 mm drop, or a slope steeper than 1:2 within 1.2 m.
- Interior stairs: where an interior stair has more than two risers, or an interior ramp rises more than 400 mm, the sides of the stair or ramp and the floor level around the stairwell must be protected by a guard on each side not protected by a wall (§629-19C(1)(c)). The basement stair in a house with a lower-level unit is the obvious one to check.
All of it sits under the general maintenance duty in §629-19A: treads, risers, guards, handrails and supporting members free from defects and hazards and in good repair.
Retaining walls in the yard
Back outside, look at the edges of the lot. A landscaped yard on a slope may have a retaining wall holding up a garden bed or a parking pad. §629-19B(1) says a retaining wall exceeding 1,000 mm in exposed height must be protected by a guard on all open sides where access to the open space is provided at the top of the wall.
The guard itself is not a separate design category. Under §629-19B(2), it is built and maintained under Subsection C or D, depending on the occupancy of the building on the property, so behind a small house it follows the Subsection C height, opening and climbing rules discussed above. Under §629-19B(3), a retaining wall on land without a building, including vacant land, follows Subsection D.
⚠️The backyard edge that gets missed: a retaining wall with more than 1,000 mm of exposed height needs a guard on all open sides where people can reach the top (§629-19B(1)). It is easy to rebuild the deck railing to the millimetre and walk past a garden wall of the same height a few steps away.
Every window that opens: screens, hardware and locks
Now step inside. Section 629-21 deals with exterior openings, and three parts of it matter for each window in a unit:
- Screens. “All windows in a dwelling unit that are capable of being opened shall be fitted and equipped with screens that are maintained in good repair and free from defects and missing components” (§629-21B). The trigger is that the window opens; there is no carve-out by floor or room.
- Weather and pests. Exterior door and window openings must be fitted with doors or windows kept weather-tight and protected by suitable materials to prevent the entry of pests (§629-21A(1)), and all exterior doors, windows, skylights and basement hatchways, including storm and screen doors and storm windows, must be in good repair and free from defects and missing components (§629-21A(3)).
- Hardware and locking. All windows capable of being opened and all exterior doors must be free from defective hardware and capable of being locked or otherwise secured from inside the building (§629-21C).
If you are reading an older summary of the by-law, one change matters. An editor’s note to §629-21 records that former §629-21E and F, which required safety devices and guards for windows in multiple-dwelling units more than two metres above grade, were repealed on April 29, 2008 by By-law No. 349-2008. Window fall protection now sits in §629-19D(4), covered next.
Windows in apartment buildings: §629-19D(4)
This rule is part of Subsection D, so it reaches buildings over three storeys or over 600 m² in building area, and §629-19D(4)(a) applies it within apartment building occupancies as described in the Building Code, to “minimize the hazards to children.” A semi-detached house within the Subsection C limits is outside it; a unit in a building that crosses those limits can be inside it. It has three operative parts:
- Fixed low windows (D(4)(b)). Fixed windows within dwelling units that extend to less than 1,000 mm from the floor must be protected by guards to at least 1,000 mm above the floor, or be designed to withstand the lateral design loads for balcony guards under D(5).
- Opening windows up high (D(4)(c)). In dwelling units, any window more than 2,000 mm above grade that opens within 1,500 mm of the floor must be protected by one of: [1] a guard conforming to D(5); [2] a controlled sash operation that restricts the opening to not more than 100 mm when engaged, and a heavy-duty screen conforming to CAN/CSA A440, “Windows”; or [3] an alternative device that does not reduce the degree of safety of [1] or [2].
- Balcony exception (D(4)(d)). Protection need not be provided in a dwelling unit where an exterior balcony is constructed for the full length of the window.
Note the “and” in option [2]: a sash restrictor on its own, without the heavy-duty screen, does not complete that option.
How the Residential Tenancies Act picks this up
Everything above applies to a property whether or not it is rented. Renting it out adds a second layer. Under the Residential Tenancies Act, 2006, s.20(1), a landlord is responsible for maintaining the residential complex and its rental units in a good state of repair and fit for habitation, and “for complying with health, safety, housing and maintenance standards.” Section 20(2) adds that this applies even if the tenant knew about the non-repair or contravention before signing the tenancy agreement, so a railing that was already short when the tenant viewed the unit does not drop out of the landlord’s duty.
On the tenant’s side, s.29(1), paragraph 1, lets a tenant or former tenant apply to the Landlord and Tenant Board for an order determining that the landlord breached s.20(1). Separately, a property standards problem can be reported to the City’s property standards enforcement; that municipal route and the Board application are different channels.
One definitional point: Chapter 629 adopts the Building Code Act meaning of “owner” (§629-1), which includes the person managing or receiving the rent, and also a lessee or occupant who, under the terms of a lease, is required to repair and maintain the property to the standards. How that interacts with s.20 in a particular lease is a question for a lawyer or licensed paralegal, not for a checklist.
Walk-around checklist
Two passes, sorted by where you are standing. Each item points to the clause it comes from.
- ☐Measure the drop at each open side of the deck, porch or balcony; if it is more than 600 mm, or the ground within 1.2 m slopes steeper than 1:2, a guard is required (§629-19C(1)(a)).
- ☐Confirm the guard height: 1,070 mm generally, or 900 mm for an exterior guard serving one unit where the surface is no more than 1,800 mm above finished ground (§629-19C(2)).
- ☐Check that a deck shared by two units is held to 1,070 mm, since the 900 mm exterior figure is written for one unit (§629-19C(2)(c)).
- ☐Test a 100 mm sphere against every opening in a required guard (§629-19C(4)(a)).
- ☐Look for footholds between 140 mm and 900 mm above the walking surface, such as a low horizontal rail (§629-19C(5)).
- ☐Find any retaining wall over 1,000 mm exposed height with access on top, and give it a guard on all open sides (§629-19B(1)).
- ☐Measure exterior step guards at 900 mm from the line through the tread nosings (§629-19C(2)(d), (e)).
- ☐Open every window that opens and check it has a screen with no tears or missing parts (§629-21B).
- ☐Lock or secure each opening window and exterior door from inside, and replace defective hardware (§629-21C).
- ☐Include storm windows, storm doors and screen doors in the repair check (§629-21A(3)).
- ☐Check guards on interior stairs with more than two risers, including the basement stair (§629-19C(1)(c)).
- ☐Confirm guards within the unit are at least 900 mm high (§629-19C(2)(b)).
- ☐In an apartment building, check windows more than 2,000 mm above grade that open within 1,500 mm of the floor for a D(5) guard, a 100 mm restrictor plus CAN/CSA A440 heavy-duty screen, or an equivalent device (§629-19D(4)(c)).
- City of Toronto Municipal Code, Chapter 629, Property Standards: §629-1 (definitions), §629-2 (application), §629-19 (stairs, guards, handrails), §629-21 (exterior openings, doors, windows), consolidation current to April 30, 2025
- Residential Tenancies Act, 2006, S.O. 2006, c. 17, ss.20(1), 20(2), 29(1) para. 1 (e-Laws current consolidation)
Mould in an Ontario Rental: Landlord Repair Duty or Tenant-Caused Damage? →RentSafeTO Explained: Which Toronto Buildings Are Covered, How They Are Scored, and What Tenants Can Look Up →How Many People Can Legally Live in One Bedroom? Ontario Occupancy Standards for Landlords →First-Time Renter Guide →
Frequently Asked Questions
I rent out the basement apartment in my detached house. Does Chapter 629 apply to that unit?
Yes. §629-2 says Chapter 629 “applies to all property in the City of Toronto,” with no exception for units within a house. The basement unit is a dwelling unit, so its opening windows need screens (§629-21B), and an interior stair with more than two risers needs guards (§629-19C(1)(c)).
My deck is only about half a metre off the ground. Does it need a railing?
Under §629-19C(1)(a), a guard is required where the drop is more than 600 mm, or where the adjacent surface within 1.2 metres slopes more than one vertical to two horizontal. A deck below 600 mm on flat ground does not meet the height trigger, but check the slope beside it. If you install a railing anyway, §629-19C(4)(c) says its openings should either stop a 100 mm sphere or let a 200 mm sphere pass, unless shown not to be a hazard.
Do storm windows and screen doors count under the property standards by-law?
Yes. §629-21A(3) names them: all exterior doors, windows, skylights and basement hatchways, “including storm and screen doors and storm windows,” must be kept in good repair and free from defects and missing components.
Does every window that opens have to lock from the inside?
§629-21C says all windows capable of being opened and all exterior doors must be free from defective hardware and “capable of being locked or otherwise secured from inside the building.” A keyed lock is not the only way to meet it; the window has to be lockable or securable from the inside.
There’s a balcony along the whole outside of my window. Do I still need window fall protection?
§629-19D(4)(d) says protection of a window need not be provided in a dwelling unit where an exterior balcony is constructed for the full length of the window. The balcony itself is then the guarded edge, and under §629-19D(1)(a) a balcony in a Subsection D building needs a guard of not less than 1,070 mm.
Discover more from GTA Real Estate Broker | Arthur Zhao
Subscribe to get the latest posts sent to your email.